Home/Texas/Amarillo

AmarilloPotter County

ESD flooring in Amarillo, to 2.5 x 104 to 1.0 x 106 ohms

A Amarillo equipment floor rarely stops, so the hard part of the job is the calendar rather than the coating. What the record shows here: data centers.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
1.0 x 106 to 1.0 x 109ohmsFAA-STD-019
under 100voltsANSI/ESD STM97.2

Amarillo, and what gets built here

These are the Amarillo operations that run static sensitive equipment, each one verified against the document named beside it.

01data centers

Fermi America's HyperGrid, a 5,800-acre campus near Amarillo

Fermi America's HyperGrid, a 5,800-acre campus near Amarillo, is planned to support 18 million sq ft of data centers on 11 GW of on-site power.

Source, verified 2026-09-05

02data centers

Google is investing $40 billion in Texas AI/cloud infrastructure through 2027

Google is investing $40 billion in Texas AI/cloud infrastructure through 2027, including a new data center in Armstrong County just outside Amarillo, part of what Google called its largest single-state investment.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

Uptime is the constraint

On a Amarillo floor the coating decision is the easy half. Sequencing it around equipment that cannot be powered down is where the real work sits.

Getting there. Crew travels from Houston/Spring (via US-287); no Texas branch nearby.

The document behind a Amarillo job

ANSI/ESD S20.20-2021 is the one worth reading first for work like this. Sets the requirements for an ESD control program, and with it the system level thresholds a qualified floor has to support.

01

What it actually governs

S20.20 is a program standard, not a product standard. It tells an organisation that handles ESD sensitive electrical or electronic parts how to run a control program: what has to be qualified, what has to be verified, and how often. Flooring is one item inside that program, which is why the standard sets a system threshold rather than a floor specification.

Questions from Amarillo

Does a Amarillo data hall need conductive or dissipative?

Your program document decides, and rooms with energized equipment often sit higher rather than lower. FAA-STD-019 specifies 1.0 x 106 to 1.0 x 109 ohms in rooms with live equipment for personnel safety[11], which is above a typical manufacturing floor.

Can you look at our Amarillo floor before we commit to anything?

Yes, and for an existing floor that is the sensible first step. Measuring what you already have against your requirement often costs a fraction of replacing it, and plenty of floors pass. What pushes a floor out of range.

Is Amarillo inside your normal service area?

Yes. Potter County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Amarillo

Crews working Amarillo cover Austin, Baytown, Conroe, Houston on the same run, so a job in Potter County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedarcat.com1staticworx.com1
2 citations on this page, across 2 publishers. Every figure above is one of them.
  1. Conductive and dissipative ESD epoxy technical data sheet, resistance and cure figures

    Cited here for the conductive flooring/coating resistance band. The ESD Association's own consumer-facing page states only the <= 1.0 x 106 ohm ceiling with no stated floor.

    www.arcat.com
  2. FAA-STD-019, floor resistance and grounding requirements for FAA facilities

    Lightning and surge protection, grounding, bonding, and shielding for FAA facilities and electronic equipment.

    staticworx.com

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.

Amarillo, Texasstatic control flooring