Sherman static control floors, built to ANSI/ESD S20.20

Wafer, probe and device work in Sherman puts two unrelated specifications on the same slab: a particle class and a resistance band. Neither standard references the other, which is what makes these rooms harder than they look. The record for Sherman shows semiconductor fab, semiconductor fab (wafer supply).

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
100percent solidsmanufacturer TDS

The measured record for Sherman

Fabrication and equipment work in Grayson County is what puts a resistance requirement on floors here, and each operation below carries the source it was checked against.

01semiconductor fab

Texas Instruments' SM1 fab in Sherman began production in December 2025 and is ramping

Texas Instruments' SM1 fab in Sherman began production in December 2025 and is ramping toward tens of millions of analog and embedded chips per day; SM2's shell is complete with cleanroom install starting later in 2026, and SM3/SM4 are planned toward a 100-million-chip-per-day goal.

Source, verified 2026-09-05

02semiconductor fab (wafer supply)

GlobalWafers America opened its first 12-inch silicon wafer fab in Sherman

GlobalWafers America opened its first 12-inch silicon wafer fab in Sherman in 2025 and is planning a second phase with an additional $4 billion investment on its 142-acre Sherman campus, including converting part of the site to silicon-carbide epitaxy wafer production.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

Two specs on one slab

In Sherman the floor is specified twice, by two standards that were written independently, and reconciling them is most of the specification work.

Getting there. Crew travels from Houston/Spring (via I-45/US-75); no Texas branch near Sherman.

The document behind a Sherman job

ISO 14644-1:2015 is the one worth reading first for work like this. Classifies cleanrooms by airborne particle concentration, ISO Class 1 through 9. Referenced when an ESD floor also has to hold a particulate rating.

01

Two requirements on one floor

A cleanroom ESD floor has to satisfy two unrelated specifications at once: a resistance band and a particulate class. They are not in conflict, but they do constrain the system, the seams and the way the floor is cleaned.

Questions from Sherman

Our floor passed at install and fails now. What changed?

In a classified room the answer is usually something applied to the surface. Anything left on top of the system sits between the floor and its ground path. Check what the cleaning regime changed before assuming the floor wore out.

How soon can you get to Sherman?

Tell us the timing you are working against and we will give you a real date rather than a placeholder. Crews work Grayson County alongside the rest of the Texas schedule. Send the details.

Do you handle the whole job in Sherman or just the coating?

The whole job: removing what is down, preparing the slab, the grounding network, the system itself and the cure schedule around your operation. Prep and grounding are where most of the work is. How it runs.

Also in Sherman-Denison

Crews working Sherman cover Austin, Baytown, Conroe, Houston on the same run, so a job in Grayson County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org1iso.org1
2 citations on this page, across 2 publishers. Every figure above is one of them.
  1. ANSI/ESD S20.20-2021, the ESD control program standard for electronics handling

    ESD control program requirements (administrative and technical) for any organization that handles ESD-sensitive electrical or electronic parts.

    www.esda.org
  2. ISO 14644-1:2015, cleanroom classification by airborne particle concentration

    Cleanroom classification by airborne particle concentration (ISO Class 1 through 9); referenced when an ESD floor also has to hold a cleanroom particulate rating.

    www.iso.org

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.