Home/Texas/Baytown

Houston-The Woodlands-Sugar LandHarris County

Baytown static control floors, built to ANSI/ESD S20.20

Processing work in Baytown treats static as an ignition source rather than a component risk, which is what pushes the specification to the tighter band. The record here: petrochemical hazardous locations.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
under 100voltsANSI/ESD STM97.2

Baytown, and what gets built here

Hazardous processing capacity in Harris County is what drives the specification here, sourced line by line.

01petrochemical hazardous locations

ExxonMobil's Baytown Complex (3,400 acres, about 7,000 workers) is mid-project

ExxonMobil's Baytown Complex (3,400 acres, about 7,000 workers) is mid-project on a Refinery Reconfiguration Project that broke ground in 2026 to expand high-performance lubricant base stock production.

Source, verified 2026-09-05

02petrochemical hazardous locations

Chevron Phillips Chemical's $8.5 billion Cedar Bayou project in Baytown is absorbing

Chevron Phillips Chemical's $8.5 billion Cedar Bayou project in Baytown is absorbing thousands of construction workers and will need roughly 500 permanent operations specialists once it starts up.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

The spark is the hazard

A Baytown processing room buys the faster band because the charge has to be gone before it can build, not merely routed somewhere safe eventually.

Getting there. Crew travels from the Spring shop (via Beltway 8/I-10).

The document behind a Baytown job

ESD TR53-01-22 is the one worth reading first for work like this. The technical report for compliance verification testing of ESD control items in service. The document your periodic floor recheck follows.

01

Qualification is day one, verification is forever

A floor is qualified once, when it goes in. TR53 is about everything after that: the recurring checks that prove the floor is still doing its job while people walk on it, clean it and wheel carts across it.

Questions from Baytown

Is conductive flooring mandatory for our Baytown area?

If it is a Department of Defense explosives area, DESR 6055.09 says yes and names the room types directly[10]. Outside that, the requirement usually comes from your own process hazard analysis rather than a code, and dissipative may be acceptable.

Do you handle the whole job in Baytown or just the coating?

The whole job: removing what is down, preparing the slab, the grounding network, the system itself and the cure schedule around your operation. Prep and grounding are where most of the work is. How it runs.

Is Baytown inside your normal service area?

Yes. Harris County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Houston-The Woodlands-Sugar Land

Crews working Baytown cover Conroe, Houston, Katy, Pasadena on the same run, so a job in Harris County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org3denix.osd.mil1
4 citations on this page, across 2 publishers. Every figure above is one of them.
  1. ANSI/ESD STM7.1-2020, floor resistance test method for static control flooring

    Floor systems resistive characterization: the test method for qualifying floor materials before installation and for accepting and monitoring them after installation.

    www.esda.org
  2. ESD Association: conductive or dissipative static control flooring, how to choose

    Cited here for the static-dissipative flooring resistance band per the ESD Association.

    www.esda.org
  3. DESR 6055.09, DoD explosives safety rule requiring conductive flooring in AA&E areas

    Explosives safety standards for DoD operations; makes CONDUCTIVE (not merely dissipative) flooring mandatory in ammunition load/assemble/pack, explosives processing, propellant casting.

    www.denix.osd.mil
  4. ESD TR53, compliance verification testing for ESD control items already in service

    Technical report for compliance verification testing of ESD control items already in service; the document a facility's periodic floor-resistance recheck follows.

    www.esda.org

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.

Baytown, Texasstatic control flooring