Conductive ESD flooring, Bastrop, Texas

Racks, dispatch desks and network positions in Bastrop carry a static requirement that comes from the equipment rather than from any production process. The record here shows aerospace manufacturing, data centers.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
1.0 x 106 to 1.0 x 109ohmsFAA-STD-019
under 100voltsANSI/ESD STM97.2

The measured record for Bastrop

Equipment capacity in Bastrop County is what drives the requirement here, not how many people live nearby. Each entry names its source.

01data centers

EdgeConneX is building a $1.44 billion, four-building data center campus in Bastrop County

EdgeConneX is building a $1.44 billion, four-building data center campus in Bastrop County (Cedar Creek); the first building, a two-story 578,000 sq ft computer warehouse ("AUS02"), carries a reported $440 million cost.

Source, verified 2026-09-05

02aerospace manufacturing

SpaceX/Starlink's Bastrop, Texas facility expanded by more than one million square feet

SpaceX/Starlink's Bastrop, Texas facility expanded by more than one million square feet, a $280 million investment creating over 400 jobs, alongside The Boring Company's manufacturing presence in the same county.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

Uptime is the constraint

A room full of energized racks changes two things about a Bastrop job. The resistance band is often set higher for the safety of the people working around live power, and the schedule stops being a detail and becomes the whole plan.

Getting there. Crew travels from Houston/Spring (via SH-71/US-290).

The document behind a Bastrop job

FAA-STD-019 is the one worth reading first for work like this. Lightning and surge protection, grounding, bonding and shielding for FAA facilities. It sets a floor resistance range above a typical ESD floor.

01

The band runs higher on purpose

FAA-STD-019 requires floor resistance between 1.0 x 106 and 1.0 x 109 ohms in rooms with energized equipment. That is above a typical manufacturing ESD floor, and the reason is personnel safety around live power rather than component protection.

Questions from Bastrop

Can you do this without taking our Bastrop room offline?

Usually, by working the space in sections around the equipment. The constraint is cure time, not application time: 24 hours before anyone walks on it at 70 F and 50 percent relative humidity[7]. Tell us how the hall is zoned and we will build the sequence backwards from your uptime requirement.

What do you need from us to price a Bastrop job?

Square footage, what is on the slab now, the resistance band your specification calls for, and the hours the space can be handed over. Four answers and we can price the actual room instead of quoting a range.

Is Bastrop inside your normal service area?

Yes. Bastrop County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Austin-Round Rock (Lockhart-Bastrop corridor)

Crews working Bastrop cover Austin, Baytown, Conroe, Houston on the same run, so a job in Bastrop County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedarcat.com1staticworx.com1
2 citations on this page, across 2 publishers. Every figure above is one of them.
  1. Conductive and dissipative ESD epoxy technical data sheet, resistance and cure figures

    Cited here for the conductive flooring/coating resistance band. The ESD Association's own consumer-facing page states only the <= 1.0 x 106 ohm ceiling with no stated floor.

    www.arcat.com
  2. FAA-STD-019, floor resistance and grounding requirements for FAA facilities

    Lightning and surge protection, grounding, bonding, and shielding for FAA facilities and electronic equipment.

    staticworx.com

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.