ESD flooring in Greenville, to 2.5 x 104 to 1.0 x 106 ohms

Aerospace ESD requirements arrive as contract language flowed down from a prime, so in Greenville the audience for your resistance records is somebody else's auditor. The record here: aerospace/avionics MRO and integration.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
400psi (concrete failure)ASTM D4541

What is actually in Greenville

Airframe, avionics and space hardware work around Greenville is where the requirement originates, each operation against a named source.

01aerospace/avionics MRO and integration

L3Harris' Greenville, Texas aerospace center spans 3.7+ million sq ft

L3Harris' Greenville, Texas aerospace center spans 3.7+ million sq ft (manufacturing, multi-sensor testing, anechoic testing, aircraft painting, and an FAA-approved flight-test range); it delivered the first MC-55A aircraft to the U.S. Air Force in January 2026 and modified King Air 350ER aircraft for Canada's MAISR program.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

The customer is the auditor

On a Greenville program the deliverable is evidence as much as coating, because the records have to survive an audit run by somebody outside your building.

Getting there. Crew travels from Houston/Spring (via I-45/I-30).

The document behind a Greenville job

ANSI/ESD S20.20-2021 is the one worth reading first for work like this. Sets the requirements for an ESD control program, and with it the system level thresholds a qualified floor has to support.

01

What it actually governs

S20.20 is a program standard, not a product standard. It tells an organisation that handles ESD sensitive electrical or electronic parts how to run a control program: what has to be qualified, what has to be verified, and how often. Flooring is one item inside that program, which is why the standard sets a system threshold rather than a floor specification.

Questions from Greenville

What records should we insist on at closeout?

Product data for the system installed, the surface preparation profile, moisture readings taken before installation, a grounding drawing, and the resistance readings mapped to floor locations. Name that package in the specification or it tends not to exist.

How soon can you get to Greenville?

Tell us the timing you are working against and we will give you a real date rather than a placeholder. Crews work Hunt County alongside the rest of the Texas schedule. Send the details.

Do you handle the whole job in Greenville or just the coating?

The whole job: removing what is down, preparing the slab, the grounding network, the system itself and the cure schedule around your operation. Prep and grounding are where most of the work is. How it runs.

Also in Dallas-Fort Worth-Arlington (Northeast)

Crews working Greenville cover Austin, Baytown, Conroe, Houston on the same run, so a job in Hunt County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org1webstore.ansi.org1
2 citations on this page, across 2 publishers. Every figure above is one of them.
  1. ANSI/ESD STM7.1-2020, floor resistance test method for static control flooring

    Floor systems resistive characterization: the test method for qualifying floor materials before installation and for accepting and monitoring them after installation.

    www.esda.org
  2. ANSI/ESD STM97.1-2025, person plus footwear plus floor system resistance test

    System resistance measurement of a person, footwear, and floor tested together; this is the test behind S20.20's under-1.0 x 109 ohm system ceiling.

    webstore.ansi.org

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.