Home/Standards/ESD TR53-01-22

Standard

ESD TR53-01-22

The technical report for compliance verification testing of ESD control items in service. The document your periodic floor recheck follows.

1.0 x 106 to 1.0 x 109ohmsANSI/ESD STM7.1
under 1.0 x 109ohmsANSI/ESD STM97.1
under 100voltsANSI/ESD STM97.2

What it means for your floor

ANSI/ESD S20.20 measures the person, their footwear and the floor as one circuit PERSONSHOES THE FLOOR, AND ITS PATH TO GROUND ONE CIRCUIT measured end to end

Under 1.0 x 109 ohms Person, footwear and floor together, under STM97.1.

Under 100 volts Walking, under STM97.2.

Change the footwear and the reading changes, which is why the floor is never qualified alone.

S20.20 qualifies a system, not a surface. The person and their footwear are inside the measurement.
01

Qualification is day one, verification is forever

A floor is qualified once, when it goes in. TR53 is about everything after that: the recurring checks that prove the floor is still doing its job while people walk on it, clean it and wheel carts across it.

02

It is a technical report, not a requirement

TR53 gives the methods. Your own program document, written to S20.20, sets how often you run them. Auditors generally want to see both: the schedule and the results.

03

This is where floors quietly fail

A floor that passed on day one and has never been rechecked is an assumption, not a control. Resistance drifts with wear and with what gets applied to the surface.

ESD TR53-01-22what it asks of a floor
Call Free quote