Conductive ESD flooring, Richardson, Texas

A classified Richardson room answers to two documents that never mention each other: a particle class and a resistance band. The record here shows semiconductor fab, telecom/data centers.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
100percent solidsmanufacturer TDS

Richardson, and what gets built here

Fabrication and equipment work in Dallas County is what puts a resistance requirement on floors here, and each operation below carries the source it was checked against.

01semiconductor fab

Texas Instruments received a $33.6 million Texas Semiconductor Innovation Fund grant tied

Texas Instruments received a $33.6 million Texas Semiconductor Innovation Fund grant tied to a roughly $700 million capital investment expanding capacity at RFAB, its 300mm wafer fab in Richardson.

Source, verified 2026-09-05

02telecom/data centers

Richardson's Telecom Corridor is home to 600+ technology companies

Richardson's Telecom Corridor is home to 600+ technology companies (AT&T, Ericsson, Samsung, Fujitsu among them), and Digital Realty operates its 69-acre "Digital Dallas" data campus in Richardson.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

Two specs on one slab

A controlled room in Richardson has to hold its particle class and its resistance band at once, and the cleaning regime that protects the first is the usual way the second gets lost.

Getting there. Crew travels from Houston/Spring (via I-45).

The document behind a Richardson job

ASTM F2170-19a is the one worth reading first for work like this. Determines relative humidity inside a concrete slab with in situ probes. This is the test a slab has to pass before an epoxy topcoat goes down.

01

Why moisture decides the job

Water vapour moving up through a slab pushes against the underside of a coating. If the slab is too wet when the system goes down, the floor can debond later regardless of how well it was installed. This is the single most common reason a resinous floor fails early.

Questions from Richardson

Our floor passed at install and fails now. What changed?

In a classified room the answer is usually something applied to the surface. Anything left on top of the system sits between the floor and its ground path. Check what the cleaning regime changed before assuming the floor wore out.

Can you look at our Richardson floor before we commit to anything?

Yes, and for an existing floor that is the sensible first step. Measuring what you already have against your requirement often costs a fraction of replacing it, and plenty of floors pass. What pushes a floor out of range.

Is Richardson inside your normal service area?

Yes. Dallas County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Dallas-Fort Worth-Arlington

Crews working Richardson cover Plano, Garland, McKinney, Dallas on the same run, so a job in Dallas County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org1iso.org1
2 citations on this page, across 2 publishers. Every figure above is one of them.
  1. ANSI/ESD S20.20-2021, the ESD control program standard for electronics handling

    ESD control program requirements (administrative and technical) for any organization that handles ESD-sensitive electrical or electronic parts.

    www.esda.org
  2. ISO 14644-1:2015, cleanroom classification by airborne particle concentration

    Cleanroom classification by airborne particle concentration (ISO Class 1 through 9); referenced when an ESD floor also has to hold a cleanroom particulate rating.

    www.iso.org

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.