Home/Texas/Plano

Dallas-Fort Worth-ArlingtonCollin County

Plano static control floors, built to ANSI/ESD S20.20

Board and device handling in Plano sits squarely inside what a static control program covers, with the floor measured as one item among several. The record here: data centers, electronics manufacturing.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
under 100voltsANSI/ESD STM97.2

The static sensitive work in Plano

Assembly and device capacity in Collin County is what drives the requirement, verified line by line.

01electronics manufacturing

Sysgration America Corporation, an electronics maker

Sysgration America Corporation, an electronics maker (industrial PCs, battery packs and industrial AR/VR glasses), announced a move into a 98,000 sq ft manufacturing facility in Plano's Research/Technology District.

Source, verified 2026-10-01

02data centers

Stack Infrastructure's planned third data center at 5601 W. Spring Creek Parkway in west

Stack Infrastructure's planned third data center at 5601 W. Spring Creek Parkway in west Plano received a planning and zoning commission recommendation of approval in July 2025.

Source, verified 2026-10-01

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

The program standard applies directly

In Plano the floor is one control item inside a program that also covers footwear, wrist straps, packaging and benches, and it gets measured with the person standing on it.

Getting there. Crew travels from Houston/Spring (via I-45).

The document behind a Plano job

ANSI/ESD STM7.1-2020 is the one worth reading first for work like this. The test method for qualifying a floor material before installation and for accepting and monitoring it afterwards.

01

Printed two ways, same document

You will see this cited as STM7.1 and as S7.1, including on manufacturer data sheets. Many report templates still print S7.1. They refer to the same floor resistive characterization method.

Questions from Plano

What does an ESD floor cost in Plano?

Most ESD floors in Texas land $8 to $16 a square foot installed, our estimate, with big continuous pours down to $6 to $8. For a sense check the wider published market runs 3.34 to 13.55 per square foot installed[8]. Where a specific room lands depends on what is on the slab now and whether the line keeps running. What moves the number.

How soon can you get to Plano?

Tell us the timing you are working against and we will give you a real date rather than a placeholder. Crews work Collin County alongside the rest of the Texas schedule. Send the details.

Is Plano inside your normal service area?

Yes. Collin County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Dallas-Fort Worth-Arlington

Crews working Plano cover Richardson, Garland, McKinney, Dallas on the same run, so a job in Collin County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org2craftsmanconcretefloors.com1webstore.ansi.org1
4 citations on this page, across 3 publishers. Every figure above is one of them.
  1. ANSI/ESD S20.20-2021, the ESD control program standard for electronics handling

    ESD control program requirements (administrative and technical) for any organization that handles ESD-sensitive electrical or electronic parts.

    www.esda.org
  2. ANSI/ESD STM97.1-2025, person plus footwear plus floor system resistance test

    System resistance measurement of a person, footwear, and floor tested together; this is the test behind S20.20's under-1.0 x 109 ohm system ceiling.

    webstore.ansi.org
  3. ESD Association: conductive or dissipative static control flooring, how to choose

    Cited here for the static-dissipative flooring resistance band per the ESD Association.

    www.esda.org
  4. ESD flooring cost per square foot installed, from 250+ commercial project bids

    Cited here for the published Texas/national ESD flooring market price range, derived from real bid data on 250+ commercial ESD projects.

    craftsmanconcretefloors.com

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.

Plano, Texasstatic control flooring
Call Free quote