Home/Texas/McKinney

Dallas-Fort Worth-ArlingtonCollin County

Static control flooring in McKinney, under 100 volts walking

When a discharge can ignite an atmosphere instead of damaging a part, the conductive band stops being a preference. McKinney carries that kind of work: defense electronics/munitions.

2.5 x 104 to 1.0 x 106ohmsANSI/ESD STM7.1 / ASTM D257 (as cited on manufacturer TDS)
under 1.0 x 109ohmsANSI/ESD STM97.1
under 100voltsANSI/ESD STM97.2

McKinney, and what gets built here

McKinney is here because of the processing and energetic materials work measured in the area. Each entry names its source.

01defense electronics/munitions

RTX's Raytheon facility in McKinney includes the Advanced Integration and Manufacturing

RTX's Raytheon facility in McKinney includes the Advanced Integration and Manufacturing Center.

Source, verified 2026-09-05

Where conductive and static dissipative sit on the resistance scale 10³10⁴10⁵10⁶10⁷10⁸10⁹10¹⁰10¹¹10¹²10¹³ CONDUCTIVE STATIC DISSIPATIVE INSULATIVE 2.5 x 10⁴ to 1.0 x 10⁶ ohms. Fastest bleed. Specified where a spark is the hazard. Anything above 10⁹ is an insulator and holds a charge instead of moving it. ANSI/ESD STM7.1 · bands published by the ESD Association
The two static control bands, drawn where they sit on the scale. Everything to the right of 10⁹ ohms is an insulator.

The program standard applies directly

A McKinney processing room buys the faster band because the charge has to be gone before it can build, not merely routed somewhere safe eventually.

Getting there. Crew travels from Houston/Spring (via I-45).

The document behind a McKinney job

NFPA 99 (2024) is the one worth reading first for work like this. The Health Care Facilities Code. It used to require conductive flooring in operating rooms. That requirement came out in 2015.

01

What changed and when

NFPA 99 historically required conductive flooring in the 2.5 x 104 to 1.0 x 106 ohm range in operating rooms using flammable anesthetics. That requirement was removed in the 2015 edition and is still absent from the current 2024 edition.

Questions from McKinney

What proves the floor is doing its job?

Point to point and point to ground resistance readings under ANSI/ESD STM7.1[2], plus a reverification schedule under ESD TR53 once it is in service[17].

How soon can you get to McKinney?

Tell us the timing you are working against and we will give you a real date rather than a placeholder. Crews work Collin County alongside the rest of the Texas schedule. Send the details.

Is McKinney inside your normal service area?

Yes. Collin County is covered on the regular Texas schedule, so a job here does not carry a travel premium the way a one off out of state trip would.

Also in Dallas-Fort Worth-Arlington

Crews working McKinney cover Richardson, Plano, Garland, Dallas on the same run, so a job in Collin County rarely stands on its own.

Sources

Publishers cited on this page, and how many times each one is citedesda.org3denix.osd.mil1
4 citations on this page, across 2 publishers. Every figure above is one of them.
  1. ANSI/ESD STM7.1-2020, floor resistance test method for static control flooring

    Floor systems resistive characterization: the test method for qualifying floor materials before installation and for accepting and monitoring them after installation.

    www.esda.org
  2. ESD Association: conductive or dissipative static control flooring, how to choose

    Cited here for the static-dissipative flooring resistance band per the ESD Association.

    www.esda.org
  3. DESR 6055.09, DoD explosives safety rule requiring conductive flooring in AA&E areas

    Explosives safety standards for DoD operations; makes CONDUCTIVE (not merely dissipative) flooring mandatory in ammunition load/assemble/pack, explosives processing, propellant casting.

    www.denix.osd.mil
  4. ESD TR53, compliance verification testing for ESD control items already in service

    Technical report for compliance verification testing of ESD control items already in service; the document a facility's periodic floor-resistance recheck follows.

    www.esda.org

Every number on this page came from one of those documents. Send us the room and we will tell you which of them your floor has to answer to.

McKinney, Texasstatic control flooring
Call Free quote