Home/Standards/ANSI/ESD STM97.2-2016

Standard

ANSI/ESD STM97.2-2016

Measures body voltage on a person walking the floor in static control footwear. This is the test behind the under 100 volt limit.

under 100voltsANSI/ESD STM97.2
15voltsANSI/ESD STM97.2

What it means for your floor

01

Resistance is not the whole answer

A floor can sit inside its resistance band and still let a person build a charge as they walk. Resistance says where a charge can go. Walking voltage says how much gets generated in the first place. S20.20 wants both answered.

02

The number to beat

Under 100 volts. For context, the system published on New Era's own ESD page measures 15 volts of body voltage generation with dissipative footwear, well inside the limit.

03

It is a walking test, deliberately

The person walks a defined path while the instrument records. Standing still on a good floor tells you very little, because the charge is generated by the separation of shoe from floor with every step.

Sources

    ANSI/ESD STM97.2-2016what it asks of a floor
    Call Get a quote